FRP I Beam (Fiberglass H Beam) Mechanical Properties – Intertek Tested
FRP I Beam, also known as Fiberglass I Beam or FRP H Beam, is a pultruded structural profile widely used in industrial platforms, chemical plants, offshore structures, and infrastructure projects. Compared with steel I beams, FRP I beams offer excellent corrosion resistance, lightweight design, and long service life.
To verify its mechanical performance, an independent third-party laboratory test was conducted by Intertek Shanghai in accordance with ASTM standards. The following content summarizes the verified test results and explains the structural advantages of FRP I beams.
FRP I Beam Test Information
| Item | Details |
|---|---|
| Product Name | FRP I Beam / Fiberglass H Beam |
| Section Size | 152 × 152 × 9.5 mm |
| Testing Laboratory | Intertek Shanghai (CMA & CNAS Accredited) |
| Report Number | 201016012SHF-005 |
| Test Standards | ASTM D638, ASTM D695, ASTM D790 |
All samples were conditioned under controlled temperature and humidity before testing to ensure accurate and repeatable results.
Tensile Properties of FRP I Beam
Tensile performance is a key indicator for load-bearing structural profiles. The FRP I beam was tested according to ASTM D638-14 in the longitudinal direction.
| Tensile Property | Result |
|---|---|
| Tensile Strength | 352 MPa |
| Tensile Modulus | 23.5 GPa |
| Elongation at Break | 1.6% |
These results demonstrate that pultruded FRP I beams provide high axial strength and stiffness while remaining significantly lighter than steel beams.
Compression Performance
Compression resistance is critical for columns, supports, and vertical structural members. Compression testing was conducted in accordance with ASTM D695-15.
| Compression Property | Result |
|---|---|
| Compressive Strength | 134 MPa |
| Compressive Modulus | 23.6 GPa |
The stable compressive modulus ensures reliable load transfer and structural safety, especially in corrosive or high-humidity environments.
Flexural Properties (Bending Performance)
Flexural performance determines the beam’s ability to resist bending under service loads. The FRP I beam was tested according to ASTM D790-17 (Procedure A).
| Flexural Property | Result |
|---|---|
| Flexural Strength | 408 MPa |
| Flexural Modulus | 20.5 GPa |
| Test Span | 152 mm |
High flexural strength makes FRP I beams suitable for walkways, platforms, cable trays, bridges, and structural framing systems.
FRP I Beam vs Steel I Beam
| Comparison Item | FRP I Beam | Steel I Beam |
|---|---|---|
| Corrosion Resistance | Excellent | Poor (Requires coating) |
| Weight | Lightweight | Heavy |
| Maintenance | Low | High |
| Electrical Insulation | Yes | No |

FRP H Beam
Custom FRP I Beam Solutions
We provide customized FRP I beam solutions to meet different project requirements, including:
- Custom cross-section sizes and fiber volume ratios
- Different resin systems (polyester, vinyl ester, epoxy)
- FRP pultrusion molds and complete production lines
- Technical support for engineering and structural applications
Contact Us for FRP I Beam Quotation
If you are looking for tested and reliable FRP I beams for your project, please contact us:
Website: www.frpzs.com
Email: Jessica@frpzs.com
WhatsApp: +86 153 0373 5673
We help global customers replace steel with advanced FRP structural solutions.
FRP I Beam Resource Hub